  #1  
Old 06-11-2010, 05:38 PM
jackbird60 jackbird60 is offline
Experienced
 
Join Date: Nov 28 2008
Posts: 124
jackbird60 is on a distinguished road
Default Gen Light On Constantly

HI, JUST BOUGHT A NICE 60 BIRD, AND THE GEN LIGHT IS ON CONSTANTLY.

SO I THOUGHT IT NEEDED A NEW GENERATOR. I FIRST MADE SURE THAT THE FIELD WIRE MATCH THE FIELD WIRE RUNNING TO THE REGULATOR. IT DID.

SO I INSTALLED THE GENERATOR , POLARIZED THE GENERATOR, AND STARTED THE CAR, AND THE GEN LIGHT IS STILL CONSTANTLY ON.

THE ONE OTHER FACTOR THAT I THINK MIGHT BE CAUSING THIS IS THE IGNITION SWITCH. IT NEEDS TO BE REPLACE BECAUSE THE ONLY WAY YOU CAN START THE CAR AND TURN OFF THE CAR, IS BY PUSHING IN ON THE IGNITION AND THEN TURNING. SAME THING TO TURN OFF.

COULD THIS BE WHY THE IGNITION LIGHT IS ON BECAUSE IT THINKS IT'S IN THE ON POSITION INSTEAD OF THE START POSITION??

JACK
Reply With Quote
  #2  
Old 06-11-2010, 06:22 PM
tbird430's Avatar
tbird430 tbird430 is offline
Super-Experienced
 
Join Date: Jun 18 2007
Posts: 2,616
tbird430 is on a distinguished road
Arrow

You might try cleaning the regulator contacts (over on the left inner fender).
__________________

The 1960 Ford Thunderbird. The WORLD'S most wanted car....

VTCI Member#6287.
Reply With Quote
  #3  
Old 06-11-2010, 06:25 PM
simplyconnected's Avatar
simplyconnected simplyconnected is offline
Slow Typist
 
Join Date: May 26 2009
Posts: 7,157
simplyconnected is on a distinguished road
Default

If your GEN light is on, it indicates three things:
1. The ignition is on,
2. The bulb is good,
3. The generator is putting out less than the battery has stored.

The GEN light is important.

How it work:
The Gen light is fed from your ignition switch with +12,
current goes through the bulb and out the firewall to your regulator (bk/y wire) on the "A" terminal.
"A" is your armature. The wire going from your regulator to your armature is 'tickled' with that small amount of current from your GEN light to produce a small amount of magnetism inside the generator. So, the other end of your armature goes straight to ground through two brushes.

Your generator isn't putting out. THIS IS A TEST: If you want to check your generator (to see if it works), pull the "F" wire off your regulator, and touch it to "B" (battery) terminal. That will put full +12 on your field, allowing your armature to produce at full capacity. Put a meter across your battery and watch it go up. If you rev your engine a little, don't let the voltage go higher than 14-volts.

Why isn't the generator puttin out?
1. Bad generator
2. Regulator isn't turning the Field on (possibly POLARIZING may correct IF the regulator is good).
3. Bad grounds on either the regulator, generator, or both. Make SURE your battery NEG is bonded to your car's body. Electricity cannot punch twelve volts through rust.
__________________
My latest project:
CLICK HERE to see my custom hydraulic roller 390 FE build.

"We've got to pause and ask ourselves: How much clean air do we need?"
--Lee Iacocca
Reply With Quote
  #4  
Old 06-11-2010, 06:26 PM
jackbird60 jackbird60 is offline
Experienced
 
Join Date: Nov 28 2008
Posts: 124
jackbird60 is on a distinguished road
Default

Thanks ~~ The Regulator Looks Very Recent And Clean But I'll Look Again. I Know The Connection Are Tight And Very Clean. Still Thinking Ignition
But Not Sure.

Jack
Reply With Quote
  #5  
Old 06-11-2010, 06:33 PM
jackbird60 jackbird60 is offline
Experienced
 
Join Date: Nov 28 2008
Posts: 124
jackbird60 is on a distinguished road
Default

Defientely Some Good Things To Check. Absolutely No Rust On The Car. Connections appear Good, I'll Recheck.

I Did Polarize Field To Batt. I'll Try Test.

Thanks
Reply With Quote
  #6  
Old 06-11-2010, 07:06 PM
JohnG's Avatar
JohnG JohnG is offline
John
 
Join Date: Jul 28 2003
Posts: 2,229
JohnG is on a distinguished road
Default

Get a multimeter so you can see what the voltage at the battery is, with it running.

(as posted) clean the contacts. Had a new one once that did not function; cleaned the points with a business card and . . . voila!

A painted, clean car does not guarantee good grounds; often not as people painted places where there used to be bare metal. Sandpaper, small files and small wire brushes are key tools. Painters and body people care about how a car looks, not how it's electrical system works.

Personally, I keep a spare VR around just for situations like this. Quick change, fast info. Next place I go is to the brush holders in the generator. Crap can cause them to no longer move, resulting in poor contact and no generation.

John
Reply With Quote
  #7  
Old 06-11-2010, 07:17 PM
jackbird60 jackbird60 is offline
Experienced
 
Join Date: Nov 28 2008
Posts: 124
jackbird60 is on a distinguished road
Default

Hi John,

Voltage runnning Is 12.6 . Not running 12.8.

I tried the Field Test where I took off the Field Wire at the Regulator and touched the Batt of the Regulator. It didn't do anything.

I took the Regulator cap off and that thing looks brand new. I checked again for contact for the wiring. As far as the Generator, that is a New/rebuilt Gen I just put in. Which is giving me the same results. Chances of 2 Gens being bad are slim I say, but who knows.

Jack

Last edited by JohnG : 06-11-2010 at 07:36 PM.
Reply With Quote
  #8  
Old 06-11-2010, 07:30 PM
JohnG's Avatar
JohnG JohnG is offline
John
 
Join Date: Jul 28 2003
Posts: 2,229
JohnG is on a distinguished road
Default

the insides of the VR almost always look new, no matter how old or malfunctioning. It is a sealed unit living in a good location.

I would get another one.

Do you still have the other generator?

These days you can take them into some auto parts stores and have them bench tested.

A better option is to open the phone book and look in the Yellow Pages under "Auto Electric". Find a shop that does rebuilds. Take all the items you have (VR and generator(s) ) in and ask them to find out what's wrong. The older and grungier the place is, the better. They will tell you the truth and you go from there.

But for starters, I would get another VR from the local auto parts guys, ought to be possible in under 24 hours as it is a common item (nothing to do with Thunderbirds per se). As I said, having a spare around is good anyway, in the event #1 is still good. I like spares - they give me options and ways to eliminate things quickly.
Reply With Quote
  #9  
Old 06-11-2010, 09:36 PM
jackbird60 jackbird60 is offline
Experienced
 
Join Date: Nov 28 2008
Posts: 124
jackbird60 is on a distinguished road
Default

Still No Luck. All Contacts Look Good. I Thought I Throw This Out There. Does It Mater If The Regulators Is 40 Amp But The Gen Is 30??

Also, Thinking Of The Alternator Solution. (maybe That Will Fix It)

Please Point Me To The Site. I Like To Know If I Can Use The Same Belt. If Not, What Kind Of Belt, (i Know Where To Buy The Bracket) And What Kind Of Alternator, And How Do I Wire It Up, And What Do I Do With Any Unused Wires.

Thanks,

Jack
Reply With Quote
  #10  
Old 06-11-2010, 09:57 PM
YellowRose's Avatar
YellowRose YellowRose is online now
Super-Experienced and a HELLOFA nice guy
 
Join Date: Jan 21 2008
Posts: 11,932
YellowRose is on a distinguished road
Default Gen Light On Constantly

Hi Jack, If you want to go the Alternator route, check this out. I think most of the guys say that a 3-wire system is better than a 1 wire system. Here is a link with a lot of information in it including wiring schematics and Richard Hord's step by step procedure.

http://www.squarebirds.org/vbulletin...ight=generator
__________________

Ray Clark - Squarebirds Administrator
'59 Tbird "The Yellow Rose Of Texas" aka "Tweety Bird"
"It's Hip To Be Square"
Thunderbird Registry #33025 VTCI #11178

rayclark07"at"att.net (Home) 210-674-5781 (Cell) 210-875-1411
http://www.squarebirds.org/picture_gallery/TechnicalResourceLibrary/trl.htm
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Forum Jump


All times are GMT -4. The time now is 01:21 PM.

Driving, racing or working on cars can be hazardous. The procedures and advice on this website including the message board are opinion only. Squarebirds.org and its webmasters and contributors do not guarantee the correctness of the advice and procedures. The Squarebirds.org and its webmasters assume no liability for any damage, fines, punishment, injury or death resulting from following these procedures or advice. If you do not have the skills or tools to repair your car, please consult a professional. By using this site you agree to hold harmless the Squarebirds.org, its authors and its webmasters from any resulting claim and costs that may occur from using the information found on this site.

Powered by vBulletin® Version 3.6.8
Copyright ©2000 - 2017, Jelsoft Enterprises Ltd.
Any submissions to this site and any post on this site becomes property of Squarebirds.org . The webmasters reserve the right to edit and modify any submissions to this site. All material on this is site is copyrighted by the Squarebirds.org. Reproduction by any means other than for personal use is strictly prohibited. Permission to use material on this site can be obtained by contacting the webmasters. Copyright 2002-2016 by Squarebirds.org.